Overhead cable for the real line

The datasheet tells you the conductor is 150 mm². The route tells you whether it needs alloy wires, grease, an insulated bundle or a fibre core. These are the six application families we support most often.

Home / Applications
Application map

Voltage, span, loading, environment

Four questions determine most overhead conductor specifications. We use them to move from a generic product family to the construction that belongs on the line.

Transmission lines

HV and EHV routes where long spans and high tensions dominate conductor selection. ACSR and AAAC are the core constructions.

Recommended range →

Distribution networks

11–33 kV feeders on wood or concrete poles, mixing AAC for short urban spans with ACSR where tension rises.

Recommended range →

Rural electrification

Village connections where insulated bundles improve safety, reduce clearances and resist illegal tapping.

Recommended range →

Service drops

Duplex, triplex and quadruplex ABC from the distribution pole to the customer’s meter, with street-light cores where required.

Recommended product →

Shield wire & telecom

OPGW and aluminium-clad steel earth wires for lightning protection, fault duty and utility telecom along the route.

Recommended range →

Renewable evacuation

Collection and export lines for solar parks and wind farms, sized to project loading and grid-code requirements.

Recommended product →
Selection matrix

From application to conductor

Transmission linesACSR for maximum tensile duty; AAAC where corrosion rules out a steel core; ACAR where ampacity must rise.
Distribution networksAAC for short urban spans and substation connections; ACSR for longer rural spans; ABC where clearance or safety demands insulation.
Rural electrificationLV ABC quadruplex mains with duplex service drops; bare ACSR feeders where budgets are tight and clearances are easy.
Service dropsDuplex, triplex or quadruplex ABC with AAAC or AAC messenger; street-light core added on the same bundle.
Shield wire & telecomOPGW where fibre is needed; aluminium-clad steel where only shielding and fault duty apply.
Renewable evacuationACSR or AAAC export lines sized to the plant capacity; OPGW for the grid-operator communication link.

Not sure which family?

Send us the line voltage, span schedule, conductor loading and environment. We will map it to a construction and explain the trade-offs.

  • Line voltage and fault duty
  • Span length and ruling tension
  • Ice, wind and temperature range
  • Coastal or industrial atmosphere
  • Telecom or fibre requirements
Start a Specification Review
On site

Where the cable actually goes

Routes, plant and project conditions from our own deliveries — the same inputs that decide the construction quoted for your line.

Line construction
Line constructionConductors delivered for an overhead line project, from tower erection through to tension stringing.
Conductor reels
Conductor reelsACSR, AAAC and AAC reels marked to the drum length agreed for the span and the pulling equipment.
Stranding
StrandingAluminium and steel strands concentric-laid to IEC 61089 and ASTM B232 requirements.
Project shipment
Project shipmentConductor reels packed and loaded for an overhead line project shipment.
Engineering support

Tell us where the line has to run.

We will recommend the conductor family and construction, then quote the exact specification.