Aluminium Clad Steel Conductor

Aluminium-clad steel stranded conductor — the corrosion-proof, high-strength earth and shield wire for overhead lines in the harshest atmospheres.

Wire standardASTM B415
Conductor standardASTM B416
Stranding3, 7, 19, 37 wires
DutyShield / earth wire, messenger
Product overview

Construction and performance

ZMS aluminium-clad steel conductor strands steel wires that carry a thick, metallurgically bonded aluminium cladding. The cladding conducts fault current and protects the steel from corrosion for the life of the line — no grease, no re-coating, no galvanic couple with aluminium phase conductors. It is the reference construction for overhead shield wires and high-strength messengers.

Construction

  • Steel core wires with bonded aluminium cladding
  • Stranding from 3 to 37 wires
  • Conductivity classes 14 % to 40 % IACS
  • No grease or coating maintenance required
  • Compatible with aluminium phase conductors and fittings

Applications

  • Overhead shield and earth wires
  • ABC messengers on long spans
  • Substation earthing conductors
  • Guy and stay wire duty

Technical data

WireAluminium-clad steel, ASTM B415
ConductorConcentric-lay stranded, ASTM B416
Stranding3, 7, 19, 37 wires
Conductivity14 %, 20.3 %, 27 %, 30 %, 40 % IACS
Breaking strengthHigh-strength and extra-high-strength grades
CorrosionBonded cladding — maintenance-free
PackingSteel or wooden drums, project lengths

Typical data; order-specific datasheets are issued with every quotation.

Selection notes

What to confirm before ordering

ACS or galvanised steel for the earth wire?
Galvanised steel is cheaper but the zinc layer eventually erodes, especially in coastal air. ACS keeps its protection for the life of the line and avoids a galvanic couple with aluminium phase conductors.
Which conductivity class should I choose?
Higher conductivity classes carry more fault current; lower classes carry more load. Match the class to the fault duty and mechanical design — we can review both.
Can ACS serve as an ABC messenger?
Yes. For long-span ABC bundles, an ACS messenger provides the highest strength-to-weight of the messenger options.

Need a sample or datasheet?

Tell us the conductivity class, section and destination. We can prepare a stranding drawing and sample for review.

Phone: +86 371 6782 9333
WhatsApp: +86 173 0383 6349
Email: [email protected]

Ask an Engineer
Engineering support

Need an earth wire matched to the fault duty?

Send us the fault current, clearing time and span schedule. We will confirm the construction and quote factory-direct.

Request a quotation

Tell us the conductor specification

Share the conductivity class, section, stranding, quantity and delivery destination. Our engineering team will reply within one business day.

    By submitting you agree to our Privacy Policy.