IEC 61089 / ASTM B232  ·  Overhead Conductor & ABC Cable Manufacturer
ZMS Cable logo
IEEE 1138 · IEC 60794-4-10

OPGW Cable

Optical fibre composite overhead ground wire — lightning shielding and utility telecom in a single conductor hung at the top of the tower.

Fibre count12–96 fibres
Optical unitStainless steel / aluminium clad
Outer strandsAluminium / ACS wires
StandardsIEEE 1138, IEC 60794-4-10
Product overview

Construction and performance

ZMS OPGW encloses single-mode optical fibres in a hermetic stainless-steel or aluminium-clad unit, stranded with aluminium or aluminium-clad steel wires to the diameter and fault-current rating the line requires. The result carries telecom traffic while performing every duty of a conventional shield wire: lightning protection, fault-current conduction and mechanical strength.

Construction

  • Loose-tube optical unit, gel-filled or dry core
  • Stainless-steel or aluminium-clad fibre tube
  • Aluminium or ACS outer strands
  • Fibre counts from 12 to 96 (higher on request)
  • Excess fibre length controlled for rated tension

Applications

  • Shield wire with integrated utility telecom
  • Protection signalling and dispatch networks
  • Fibre leasing along transmission corridors
  • SCADA and substation communication links

Technical data

FunctionOverhead ground wire with optical fibres
Fibre count12–96 single-mode (G.652.D)
Optical unitStainless steel or aluminium-clad tube
Outer strandsAluminium / aluminium-clad steel
Fault-current dutySized to system requirements
StandardsIEEE 1138, IEC 60794-4-10, ITU-T G.652
PackingSteel drums, project-specific lengths

Typical data; order-specific datasheets are issued with every quotation.

Selection notes

What to confirm before ordering

What fault-current rating do I need?
The OPGW must survive the maximum earth fault current for its clearing time without fibre damage. Send the fault level and clearing time; we will size the conductive cross-section accordingly.
How many fibres should I specify?
Common counts are 24, 48 and 96. Specify for current needs plus spare capacity — the fibre count cannot be increased after stringing.
Can OPGW replace an existing shield wire?
Yes, provided diameter, weight and breaking load are compatible with the existing towers and fittings. Send the existing wire data and we will confirm the match.

Need a sample or datasheet?

Tell us the fibre count, fault duty and destination. We can prepare a construction drawing and sample for review.

Phone: +86 371 6782 9333
WhatsApp: +86 173 0383 6349
Email: [email protected]

Ask an Engineer
Engineering support

Need an OPGW matched to the line design?

Send us the fault-current duty, fibre count and span schedule. We will confirm the construction and quote factory-direct.

Request a quotation

Tell us the OPGW specification

Share the fibre count, fault-current duty, span schedule, quantity and delivery destination. Our engineering team will reply within one business day.

    By submitting you agree to our Privacy Policy.